Sensor
|
Manufacturer
|
Max Depth (m)
|
Range
|
Accuracy
|
|
Conductivity
|
RBR Inductive
|
6,600
|
0 to 70
mS/cm
|
±0.003
|
|
Conductivity
|
RBR 3 Electrode
|
2,000
|
0 to 2 mS/cm
|
±0.003
|
|
Temperature
|
RBR Thermometrics
|
10,500
|
-40 to +35ºC
|
±0.002
|
| Thermistor
string |
RBR
Thermometrics |
8,500m
|
-40 to +35ºC
|
±0.005
|
|
Depth
|
RBR Honeywell
|
6,600
|
0 to 6,600
|
±0.05%
|
|
Depth
|
Paroscientific
/ Serial
|
10,000
|
0 to 10,000
|
±0.015%
|
|
pH
|
AMT
|
1,200 / 6,000
|
0 to 14
|
±0.1
|
|
ORP
|
AMT
|
1,200 / 6,000
|
-2 to +2 V
|
±0.01
|
|
DO
|
Oxyguard
|
100 / 2,000
|
0 to 150%
|
±1%
|
|
DO
|
Aanderaa
Optode
|
6,000
|
0 to 120%
|
±5%
|
|
Turbidity
|
Seapoint
|
6,000
|
0 to 2000
FTU
|
<±2%
|
|
Turbidity
|
D&A
Instruments
|
500 |
0
to 2000 FTU |
±1% |
|
Fluorometer
|
Seapoint
|
6,000
|
0.02 - 150 µg/L
|
<±2%
|
|
Fluorometer
|
Wetlabs
|
600 |
0.03
- 75 µg/L |
|
|
Transmissometer
|
Wetlabs
|
600 / 6,000
|
660, 530, 470, or 370 nm
|
|
|
PAR
|
Licor
|
560
|
0-10,000µmol/s-m2
|
<±2%
|
|
PAR (5 decade)
|
BioSpherical
|
2,000
|
0-5,000µmol/s-m2
|
<±2%
|
|
Heading
|
Precision
Navigation
|
Internal
|
0-360º
|
±0.1
|
|
Tilt
|
Precision
Navigation
|
Internal
|
±50º
|
±0.2
|
|
Tilt
|
RST
InstrGeological
|
|
±40º
|
±0.01º
|
|
Altitude
|
Benthos
|
1,000 / 6,000
|
0 to 100m
|
±0.05m
|
|
| Data
Logger Accessories |
| To support
your purchase / measurement program, RBR Ltd provide a range of
accessories as detailed below: |
|
![[Logger-PC Cable]](images/rbrcable_leaf.gif) |
Data/Power
Cables |
A
serial data download cable is shipped with every logger order. The cable
is for downloading the data from your RBR logger to a PC. Cable
Specifications |
|
| |
Batteries |
RBR
loggers come with one set of batteries. All current RBR loggers use a
common camera battery: 2/3A 3V lithium. These batteries can be purchased
virtually anywhere that film and camera equipment is sold. |
|
 |
Transit
Case |
RBR
now offers a range of rugged transit cases.
These provide the best possible protection for our precision data
recorders. Each case comes
with foam inserts that may be cut to suit the instruments and accessories.
They may be used for shipping and storage and ensure that the
instruments are ready at all times for deployment. |
|
 |
Mooring
Clamp |
RBR
makes mooring clamps for all the XR-series loggers, the TR-1050, DR-1050,
and TDR-2050. The clamps are manufactured out of 25mm
blue nylon and come with a M6 titanium bolt and nut. The mooring hole size
may be specified by the customer. |
|
 |
Mounting
Clamp |
We
offer clamps for mounting external sensors on our XR-series loggers. |
|
![[Sensor Guard]](images/rbrguard_XR-420_sm.gif) |
Sensor
Guards |
RBR
makes sensor guards for titanium XR-series loggers. The plastic XR-series
loggers, which have built-in guards for the pressure and temperature
sensors, do not require this unless equipped with extra
sensors, such as pH and ORP. |
|
 |
Cage |
RBR
offers cages for multi-sensor loggers. Cages are made from 1/4" 316
stainless and can easily accommodate a variety of different sensors and
configurations; for profiling or moored applications. |
|
| |
Software |
|
|
Full details of the complete range of
products and services available from RBR Ltd. can be obtained from www.rbr-global.com
or by contacting them via the following address / numbers:
|
|
Address:
|
RBR Ltd.
27 Monk St.
Ottawa, Ontario
CANADA K1S 3Y7
|
|
Phone:
|
(613) 233-1621
|
|
Fax:
|
(613) 233-4100
|
|
E-mail:
|
info@rbr-global.com
|
|